YMGI WMMS-30CH-V2B(59)4 (2-Zone)
$1,935.00
DC Inverter 21SEER, Outdoor Unit-Dual Zone, up to 32K Btu/h
Description
- Zone (Indoor Unit Qty.):2
- Allowed Indoor Unit Capacity Rating Total: 32,000 Btu/h
- Allowed Indoor Unit Max. Qty.: 2
- Required Indoor Unit Min. Qty. 1
Line Sets/ Wires not included
Out of stock
Description
DC Inverter 21SEER, Outdoor Unit-Dual Zone, up to 32K Btu/h
Description
- Zone (Indoor Unit Qty.):2
- Allowed Indoor Unit Capacity Rating Total: 32,000 Btu/h
- Allowed Indoor Unit Max. Qty.: 2
- Required Indoor Unit Min. Qty. 1
| YMGI Specifications: DC Inverter Mini Split Heat Pump-Multiple Zone-(59)4 Outdoor Units 22 SEER | ||
| Model | Units | WMMS-30CH-V2B(59)4 |
| Cooling Capacity Rating-Standard Comp. Speed | Btu/h | 18000 |
| Min./Max. Cooling Capacity | Btu/h | 6998 / 21000 |
| Heating Capacity Rating-Standard Comp. Speed | Btu/h | 19000 |
| Min./Max. Heating Capacity | Btu/h | 7000 / 22600 |
| Max. Allowed IDU Qty./Capacity Total | # / Btu/h | 2 / 30,000 |
| EER W/W, (Btu/h)/W | W/W | 3.66 / 12.50 |
| COP W/W, (Btu/h)/W | W/W | 3.66 / 12.50 |
| SEER / HSPF | – | 22.00 / 10.50 |
| Air Flow Volume | CFM | 1883 |
| Sound Pressure / Power Level | dB(A) | 56 / 63 |
| Power Supply | V/Ph/Hz | 208-230/1/60 |
| Power Cable Conductor Minimum Size | AWG | AWG 14, Following NEC |
| Recommended HVAC Type Circuit Breaker Size | Amp. | 20 |
| Power Input Cooling / Heating / Rated | KW | 1.44 / 1.52 / 2.80 |
| Current Input Cooling / Heating / Rated | A | 6.26 / 6.61 / 12.42 |
| Compressor Type, Model | – | Inverter Rotary, LD QXA- B141zF030A |
| Compressor Capacity / Input | W | 4320 / 1440 |
| Compressor RLA / LRA | A | 10.82 / – |
| Compressor Thermal Protector KINGERSONS | – | Exterior 1NT11L—6233 |
| Compressor Crankcase Heater | W | 25 |
| Compressor Oil Type, Charge | -, OZs | RB68EP, 13.7 |
| De-Ice/Snow Heater Power Input | W | 96 |
| De-Ice/Snow Heater Current | A | 0.4 |
| Fan Type / Qty. / Diameter-Height | – | Axial-flow / 1 /D550-H65mm |
| Motor Model / Type | – | LW60M-ZL, DC |
| Motor Insulation Class, Safe Class | – | E, IPX4 |
| Fan Motor Drive Type, Speed | – | Director Drive, 630 |
| Fan Motor Power Output / Input | W | 60 / – |
| Motor Full Load Amp (FLA) | A | – |
| Condenser Materials | – | Aluminum Fin-Copper Tube |
| Permissible Operating Pressure for the Discharge/Suction Sides | PSI | 600 / 360 |
| High/Low Pressure Overload Protector | PSI | 580 / – |
| Cooling Operation Ambient Temperature Range | F | 0 ~ 118 |
| Heating Operation Ambient Temperature Range | F | -4 ~ 75 |
| Defrosting Method of Heat Pump in Low Temperature Ambient |
— | Automatic Reversing, Fan Cycling |
| Pressure Maitenance Method in Low Temperature Cooling |
— | Automatic Fan Speed Control, Cycling |
| Overload Protector | – | Current+Temperature |
| Designed for Climate Type, Moisture Protection | – | T1, IPX4 |
| Refrigerant, Charge | LBs | R410A, 3.5 |
| Metering Device KINGERSONS | – | Electronic expansion valve |
| Flare/Nut Valve Size-Liquid | Inch | 1/4, 1/4 |
| Flare/Nut Valve Size-Gas | Inch | 3/8, 3/8 |
| Min. Allowed Copper Line Length/Unit | Ft. | 15 |
| Max. Allowed Copper Line Length- outdoor to last indoor unit |
Ft. | 65 |
| Max. Elevation Difference Allowed- outdoor unit is below all indoor units |
Ft. | 35, Oil Trap is Not Needed |
| Max. Elevation Difference Allowed- outdoor unit is above indoor units |
Ft. | 35, Oil Trap is Suggested Every 18′ |
| Max. Copper Line Length (all together) | Ft. | 130 |
| No Additional Refrigerant Needs to be Added, If Copper Line Length Total is Less Than | Ft. | 60 |
| Refrigerant Charge Rate, If Needed, by Weight/Ft. of Extra Liquid Line Length |
Ozs/Ft. | 2.32 |
| Dimension of Unit Outline (W×D×H) | Inch | 37.6×15.6×27.6 |
| Dimension of Package (W×D×H) | Inch | 40.5×18.0x29.5 |
| Weight-Net / Gross | LBs | 115 / 124 |