YMGI WMMS-48CH-V2B(59)4 (5-Zone)

$2,830.00

DC Inverter 21SEER, Outdoor Unit-Quad Zone, up to 57K Btu/h

Description

  • Zone (Indoor Unit Qty.): 2-5 Zones
  • Allowed Indoor Unit Capacity Rating Total: up to 48,000 Btu/h
  • Allowed Indoor Unit Max. Qty.: 5
  • Required Indoor Unit Min. Qty. 2

Line Sets/ Wires not included

Description

DC Inverter 21SEER, Outdoor Unit-Quad Zone, up to 57K Btu/h

Description

  • Zone (Indoor Unit Qty.): 2-5 Zones
  • Allowed Indoor Unit Capacity Rating Total: up to 48,000 Btu/h
  • Allowed Indoor Unit Max. Qty.: 5
  • Required Indoor Unit Min. Qty. 2
YMGI Specifications: DC Inverter Mini Split Heat Pump-Multiple Zone-(59)4 Outdoor Units 21SEER
Model Units WMMS-48CH-V2B(59)4
Cooling Capacity Rating-Standard Comp. Speed Btu/h 34000
Min./Max. Cooling Capacity Btu/h 8871 / 35826
Heating Capacity Rating-Standard Comp. Speed Btu/h 42500
Min./Max. Heating Capacity Btu/h 8871 / 44356
Max. Allowed IDU Qty./Capacity Total # / Btu/h 5 / 48,000
EER W/W, (Btu/h)/W W/W 3.66 / 12.5
COP W/W, (Btu/h)/W W/W 3.70 / 12.62
SEER / HSPF 21.00 / 10.50
Air Flow Volume CFM 4531
Sound Pressure / Power Level dB(A) 61 / 71
Power Supply V/Ph/Hz 208-230/1/60
Power Cable Conductor Minimum Size AWG AWG10, Following NEC
Recommended HVAC Type Circuit Breaker Size Amp. 40
Power Input Cooling / Heating / Rated KW 2.72 / 3.37 / 3.80
Current Input Cooling / Heating / Rated A 11.84 / 14.64 / 16.86
Compressor Type, Model Inverter Rotarty, LD QXAS- D32zX090A
Compressor Capacity / Input W 12300 / 4150
Compressor RLA / LRA A 15.6 / –
Compressor Crankcase Heater W 40
Compressor Oil Type, Charge -, OZs FV50S, 35.2
De-Ice/Snow Heater Power Input W 96
De-Ice/Snow Heater Current A 0.4
Fan Type / Qty. / Diameter-Height Axial-flow / 1 /D570-H152mm
Motor Model / Type SWZ150B, DC
Motor Insulation Class, Safe Class E, IPX4
Fan Motor Drive Type, Speed Director Drive, 880
Fan Motor Power Output / Input W 170 / 240
Motor Full Load Amp (FLA) A 0.82
Condenser Materials Aluminum Fin-Copper Tube
Permissible Operating Pressure for the Discharge/Suction Sides PSI 600 / 360
High/Low Pressure Overload Protector PSI 580 / –
Cooling Operation Ambient Temperature Range F 0 ~ 118
Heating Operation Ambient Temperature Range F -4 ~ 75
Defrosting Method of Heat Pump in
Low Temperature Ambient
Automatic Reversing, Fan
Cycling
Pressure Maitenance Method in Low
Temperature Cooling
Automatic Fan Speed Control,
Cycling
Overload Protector Current+Temperature
Designed for Climate Type, Moisture Protection T1, IPX4
Refrigerant, Charge LBs R410A, 8.0
Metering Device KINGERSONS Electronic expansion valve
Flare/Nut Valve Size-Liquid Inch 1/4, 1/4, 1/4, 1/4, 1/4
Flare/Nut Valve Size-Gas Inch 3/8, 3/8, 3/8, 3/8, 3/8
Min. Allowed Copper Line Length/Unit Ft. 15
Max. Allowed Copper Line Length-
outdoor to last indoor unit
Ft. 80
Max. Elevation Difference Allowed-
outdoor unit is below all indoor units
Ft. 50, Oil Trap is Not Needed
Max. Elevation Difference Allowed-
outdoor unit is above indoor units
Ft. 50, Oil Trap is Suggested
Every 25′
Max. Copper Line Length (all together) Ft. 246
No Additional Refrigerant Needs to be Added, If Copper Line Length Total is Less Than Ft. 150
Refrigerant Charge Rate, If Needed, by
Weight/Ft. of Extra Liquid Line Length
Ozs/Ft. 2.32
Dimension of Unit Outline (W×D×H) Inch 42.8×17.3×43.4
Dimension of Package (W×D×H) Inch 45.6×19.4×48.6
Weight-Net / Gross LBs 198 / 216