YMGI WMMS-18K-V2B(57)3 M1

$1,100.00

Single Zone 16 SEER
Line Sets/Wires Not Included

Description

Series (57)-16 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)

Indoor Unit Model: WMMS-18E-V2B(57)3
Outdoor Unit Model: WMMS-18C-V2B(57)3

DC Inverter 16 SEER, 18,000 Btu/h, 208-230/1/60

Indoor Unit WMMS-18E-V2B(57)3
Outdoor Unit WMMS-18C-V2B(57)3
Power supply V/Ph/Hz 208-230V/1/60Hz
Cooling Nominal Capacity Btu/h 18000
Input W 1700
Rated current Amp. 7.4
EER Btu/h.w 9.7
SEER Btu/h.w 16.0
Heating Capacity Btu/h 18000
Input W 1600
Rated current Amp. 7.1
COP W/W 3.20
HSPF Btu/h-w 8.50
Minimum Circuit Ampacity Amp. 15
MAX HVAC Type
Circuit Breaker
Amp. 20
Compressor Model ATD141RDPA8JT
Type Rotary
Brand HIGHLY
Capacity Btu/h 5560
Input W 1255
Rated current(RLA) Amp. 4.2
Refrigerant oil/oil charge ml α68HES-H or
equivalent
480±20ml
Indoor fan motor Model YDK-50C-4P 3 A050501000360-R0
Brand CG
Input W 54
RLA Amp. 0.22
LRA Amp. 0.41
Winding Resistance Ω 203/169
Capacitor uF 1.8
Speed
(Hi/Me/Lo)
rpm 1300±20
1150±20
1000±20
Indoor air flow (Hi/Me/Lo) CFM 471 / 417 / 362
Indoor
noise level (Hi/Me/Lo)
dB(A) 47
Indoor unit Dimension (WxDxH) Inch 35x11x8
Packing WxDxH) Inch 39x15x12
Net/Gross
weight
lbs. 29/33
Outdoor fan motor Model YDK-40-6C 1 H3 A050501000238-R0
Brand CG
Input W 85
RLA Amp. 0.37
LRA Amp. 0.60
Winding Resistance Ω 107/100.8
Capacitor uF 3
Speed Rpm/M 670 /870
Outdoor air flow CFM 1159 / 1200
Outdoor noise level dB(A) 53 / 41
Outdoor unit Dimensions (WxDxH) Inch 33.46” x 11.49” x 23.85”
Packing (WxDxH) Inch 39x16x27
Net/Gross weight lbs. 88/99
R410A Refrigerant charge Oz 45.92
Refrigerant precharge maximum pipe length Ft. 25
Additional charge for each ft. Oz 0.23
Design pressure PSIG 510/250
Refrigerant piping Liquid side/
Gas side
Inch 1/4″+1/2″
Max. refrigerant pipe length Ft. 49.2
Max. difference in level Ft. 16.4
Connection wires between IDU and ODU 4×AWG18
Control Type Remote Control
Operation Temperature Ranges Indoor (cooling/ heating) °F 61~90
Outdoor
(cooling / heating)
°F AC: 15~115 /
HP: -4 ~ 75
Application area
(cooling standard)
Sq. ft. 258~450

Important Notes:

  1. Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
  2. Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
  3. Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.