YMGI (59) Series DC Inverter Dual Zone-Outdoor Unit (59)4 is a 36k Btu system that runs quietly and efficiently for any 3 room application. The system comes with three 9k console indoor units that can be mounted to the floor or wall. This 3 Zone outdoor condensing unit has an 21 SEER rating. With heating and cooling capacities of 48k Btu that are powered by 208-230 volt, 1 phase, 60Hz. The compact outdoor unit allows for ground installation, or mounting in a variety of discreet locations, including on a wall, on a roof, under a deck or even on a balcony. Includes 5 x 25′ Copper Line sets and Wires, and Free Shipping

Out of stock

SKU: 3X09EL-WMMS-36CH-V2B(59)4 Categories: , , ,

Description

DC Inverter Mini System-Multiple Zone-(59)4 21 SEER
CHOIR Outdoor Units 3 Zone 36k Btu/h

Outdoor Unit Models WMMS-36CH-V2B(59)4
(1 to 3)
Power Supply 208-230/1/60
Cooling Capacity* (Btu/h) Max. IDU Cap.
Total 2
36,000
(2 Thermal Zones)
Rated 1 24,000
Min 7,500
Total Power Input in Cooling Mode* (W) Max. 3300
Rated 2250
Min. 800
SEER Btu/h 21.00
HSPF Btu/h 10.50
Heating Capacity* (Btu/h) Max. IDU Cap.
Total 2
38,000
Rated 1 26,000
Min. 7,500
Total Power Input in Heating Mode* Max. 3000
Rated 2500
Min. 800
Liquid Valve Size In 3 x 1/4”
Gas Valve Size In 3 x 3/8”
Compressor Oil RB68EP
L.R.A. A 45
Compressor RLA A 15.82
Compressor Power Input W 2550
MCA A 20
Fuse or Circuit Breaker (HVAC Type) A 30
Throttling Method Electronic Expansion Valve
Starting Method Transducer starting
Recommended Working
Ambient Temp Ranges
°F AC: 0 ~ 118
HP:-4 ~ 75
Condenser Aluminum fin-copper tube
Output of Fan Motor W 90
Fan Motor RLA A 0.65
Fan Motor
Capacitor
uF 3.5
Fan Type-Piece Axial-flow 1
Fan Diameter In. 21.65
Defrosting Method Auto Defrost
Climate Type T1
Isolation I
Moisture Protection IP24
Max. Operating Pressure at High Side PSI 550
Max. Operating Pressure at Low Side PSI 175
Sound Pressure Level dB (H/L) A 59
Sound Power Level dB (H/L) A 69
Outdoor Unit Dimensions (WxHxD) In. 38.6 × 31.1 × 13.4
Package Dimensions (WxHxD) In. 42.63 × 33.63 × 19.22
Net /Gross Weight LBs 153/164
R410A Refrigerant/
Factory Pre-Charge for 25’
LBs 4.85
Maximum drive IDU NO. 3
WMMS-36CH-V2B(59)4
Total length (actual length) of fitting pipe ≤ 200 ft
Length of farthest fitting pipe ≤ 60 ft
Height difference between
outdoor unit and indoor unit
Outdoor unit
at upper
≤ 60 ft
Outdoor Unit
at lower
≤ 50 ft
Height difference between indoor units ≤ 25 ft

 

Model WMMS-09EL-V2B(59)2
Cooling Capacity Btu/h 9500
Heating Capacity Btu/h 11000
Power Supply V/Ph/Hz 208 / 230 / 1 / 60
Power Consumption W 15
Airflow Volume m3/h 400
CFM 235
Related Current
Heating / Cooling
Amp 0.4
MCA Amp 0.5
MOP Amp 15
Sound
Pressure Level
dB(A) 38
Refrigerant R410A
Connection Pipes
Liquid Connecting Pipe
Diameter
in. Ø1/4
Gas Connecting
Pipe Diameter
in. Ø3/8
Drain Pipe
External Diameter
in. Ø 0.67
Drain Pipe
Internal Diameter
in. Ø 0.59
Dimensions & Weight Indoor Unit
Dimensions (W x D x H) in. 27 5/9 x 8 1/2 x 23 5/8
Net/Gross Weight lbs. 35.3/ 41.9