YMGI Floor/Ceiling Mount 09k WMMS-09EU-V2B(59)2 16 SEER

$865.00

(59)2 DC Inverter Multiple Zone-Indoor Units-Ceiling/Floor Unit EU, 09K Btu/h, 208-230/1/60

Description

(59)2 DC Inverter Multiple Zone-Indoor Units-Ceiling/Floor Unit EU, 09K Btu/h, 208-230/1/60

Items Unit / Conditions WMMS-09EU-V2B(59)2
Power Supply Voltage/Ph/Hz 208-230/1/60
Allowed Voltage Range 187-253V
Cooling Capacity High/Standard/Low 10700/8500/4600
Heating Capacity ID 70/60, OD 47/43F 9500
ID 70/60, OD 17/15F 8800
ID 70/60, OD 17/5F 8000
SEER Btu/h.W 16
HSPF Btu/h.W 8.2
Dehumidifying Capacity Pints/Hr. 1.7
Air Flow (CFM) High/Medium/Low 383/324/265
Air-throw (Ft.) Horizontal Installation 35-30 Upon Mounting Height/Speed/Temp.
Upright Installation 35-20 Upon Mounting Location/Speed/Temp.
External Static Pressure Water In. 0
Sound Level Pressure dB(A) (H/M/L) 40/38/36
Power dB(A) (H/M/L) 50/48/46
Fan Motor Model FG10A
Shaft Double
Speed (RMP, H/M/L) 690/610/480
Output (W) 15
Input (W) 55
Capacitor (uF) 1
Fan Wheel Type-Piece Centrifugal-2
Diameter x Width (In.) 5.5 x 4.1
Swing/Step Motor Model MP35CB
Piece 2
Output (W) 2
Input Power of Ele. Heater Type-W NA
Electrical Protection Fuse PCB/Transformer T3.15A 250V / 0.2A
Evaporator Coil Type Alu. Fin/Inner Grooved Copper Tube
Color Blue or the Like
Copper Line Connections Sealed by Dry Nitrogen Yes
Flare/Nut-Liuqid + Gas 1/4″ + 3/8″
Drain Hose Connection OD (In.) 0.67
Condensate Pump Installed-Lift (In.) NA
Refrigerant Environmental Friendly R410A
Filter Type-Feature Standard-Washable
Size WxH (In.) – Qty. 21.8 x 8.68 – 2
Clean Coil Surface Anti-Mildew Function Yes
Pre-heating Function Anti-Cold Blowing Yes
Memory of Previous Set-ups Power is Lost/Resumed Yes
Auto-Restart Function If Power is Resumed Yes
Unit Dimensions Net WxHxD (In.) 48 x 27.6 x 8.9
Package WxHxD (In.) 52.8 x 32.3 x 11.8
Unit Weight Net (LBs) 88
Packaged (LBs) 110
Loading Capacity 20’/40’/40’HQ 66/132/132