YMGI WMMS-09K-V2A(57)2 M1
$729.00
Single Zone 16 SEER
Line Sets/Wires Not Included
Description
Series (57)-16 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control), 09K, 115/1/60
Indoor Unit Model: WMMS-09E-V2A(57)2
Outdoor Unit Model: WMMS-09C-V2A(57)2
DC Inverter 16 SEER, 9,000 Btu/h, 115/1/60
Indoor Unit | WMMS-09E-V2A(57)2 | |||
Outdoor Unit | WMMS-09C-V2A(57)2 | |||
Power supply | V/Ph/Hz | 115V/1/60Hz | ||
Cooling | Nominal Capacity | Btu/h | 9000 | |
Input | W | 890 | ||
Rated current | Amp. | 8.6 | ||
EER | Btu/h.w | 10.5 | ||
SEER | Btu/h.w | 16.0 | ||
Heating | Capacity | Btu/h | 11000 | |
Input | W | 1020 | ||
Rated current | Amp. | 9.9 | ||
COP | W/W | 3.16 | ||
HSPF | Btu/h-w | 8.20 | ||
Minimum Circuit Ampacity | Amp. | 15 | ||
MAX HVAC Type Circuit Breaker |
Amp. | 20 | ||
Compressor | Model | 5RS092ZJB21 | ||
Type | Rotary | |||
Brand | Panasonic | |||
Capacity | Btu/h | 7882 | ||
Input | W | 915 | ||
Rated current(RLA) | Amp. | 4.1 | ||
Refrigerant oil/oil charge | ml | FV50S or equivalent 320ml |
||
Indoor fan motor | Model | YDK-16-4 L4 | ||
Brand | CG | |||
Input | W | 40 | ||
RLA | Amp. | 0.30 | ||
LRA | Amp. | 0.32 | ||
Winding Resistance | Ω | 140/118.5 | ||
Capacitor | uF | 4 | ||
Speed (Hi/Me/Lo) |
rpm | 1250±20 1100±30 800±40 |
||
Indoor air flow (Hi/Me/Lo) | CFM | 524/285/207 | ||
Indoor noise level (Hi/Me/Lo) |
dB(A) | 42 | ||
Indoor unit | Dimension (WxDxH) | Inch | 31x11x8 | |
Packing WxDxH) | Inch | 38x14x12 | ||
Net/Gross weight |
lbs. | 22/26 | ||
Outdoor fan motor | Model | YDK-35-6HD 3 A050501000163-R0 | ||
Brand | CG | |||
Input | W | 79 | ||
RLA | Amp. | 0.66 | ||
LRA | Amp. | 0.86 | ||
Winding Resistance | Ω | 52.5/51.5 | ||
Capacitor | uF | 8 | ||
Speed | Rpm/M | 900/600 | ||
Outdoor air flow | CFM | 1147 / 765 | ||
Outdoor noise level | dB(A) | 53 / 35 | ||
Outdoor unit | Dimensions (WxDxH) | Inch | 28.74” x 9.44” x 21.18” | |
Packing (WxDxH) | Inch | 34x13x24 | ||
Net/Gross weight | lbs. | 60/64 | ||
R410A Refrigerant charge | Oz | 31.68 | ||
Refrigerant precharge maximum pipe length | Ft. | 25 | ||
Additional charge for each ft. | Oz | 0.23 | ||
Design pressure | PSIG | 510/250 | ||
Refrigerant piping | Liquid side/ Gas side |
Inch | 1/4″+3/8″ | |
Max. refrigerant pipe length | Ft. | 49.2 | ||
Max. difference in level | Ft. | 16.4 | ||
Connection wires between IDU and ODU | 4×AWG18 | |||
Control Type | Remote Control | |||
Operation Temperature Ranges | Indoor (cooling/ heating) | °F | 61~90 | |
Outdoor (cooling / heating) |
°F | AC: 15~115 / HP: -4 ~ 75 |
||
Application area (cooling standard) |
Sq. ft. | 129~200 |
Important Notes:
- Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
- Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
- Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.