YMGI WMMS-12K-V2A(57)2 M1

$800.00

Single Zone 16 SEER
Line Sets/Wires Not Included

Out of stock

Description

Series (57)-16 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control), 115/1/60

Indoor Unit Model: WMMS-12E-V2A(57)2
Outdoor Unit Model: WMMS-12C-V2B(57)2

DC Inverter 16 SEER, 12,000 Btu/h, 115/1/60

Indoor Unit WMMS-12E-V2A(57)2
Outdoor Unit WMMS-12C-V2A(57)2
Power supply V/Ph/Hz 115V/1/60Hz
Cooling Nominal Capacity Btu/h 12000
Input W 1180
Rated current Amp. 11.4
EER Btu/h.w 10.2
SEER Btu/h.w 16.0
Heating Capacity Btu/h 13000
Input W 1300
Rated current Amp. 12.5
COP W/W 3.16
HSPF Btu/h-w 8.20
Minimum Circuit Ampacity Amp. 18
MAX HVAC Type
Circuit Breaker
Amp. 30
Compressor Model 5RS102ZBC21
Type Rotary
Brand Panasonic
Capacity Btu/h 8922
Input W 1010
Rated current(RLA) Amp. 4.4
Refrigerant oil/oil charge ml FV50S or
equivalent
320ml
Indoor fan motor Model YDK-16-4 L4
Brand CG
Input W 40
RLA Amp. 0.30
LRA Amp. 0.32
Winding Resistance Ω 140/118.5
Capacitor uF 4
Speed
(Hi/Me/Lo)
rpm 1250±20
1100±30
800±40
Indoor air flow (Hi/Me/Lo) CFM 353 / 311 / 206
Indoor
noise level (Hi/Me/Lo)
dB(A) 42
Indoor unit Dimension (WxDxH) Inch 31x11x8
Packing WxDxH) Inch 38x14x12
Net/Gross
weight
lbs. 22/26
Outdoor fan motor Model YDK-35-6HD 3 A050501000163-R0
Brand CG
Input W 79
RLA Amp. 0.66
LRA Amp. 0.86
Winding Resistance Ω 52.5/51.5
Capacitor uF 8
Speed Rpm/M 900/600
Outdoor air flow CFM 1147 / 765
Outdoor noise level dB(A) 53 / 35
Outdoor unit Dimensions (WxDxH) Inch 31.96” x 10.11” x 21.25”
Packing (WxDxH) Inch 36x13x23
Net/Gross weight lbs. 71/75
R410A Refrigerant charge Oz 39.52
Refrigerant precharge maximum pipe length Ft. 25
Additional charge for each ft. Oz 0.23
Design pressure PSIG 510/250
Refrigerant piping Liquid side/
Gas side
Inch 1/4″+3/8″
Max. refrigerant pipe length Ft. 49.2
Max. difference in level Ft. 16.4
Connection wires between
IDU and ODU
4×AWG18
Control Type Remote Control
Operation Temperature Ranges Indoor (cooling/ heating) °F 61~90
Outdoor
(cooling / heating)
°F AC: 15~115 /
HP: -4 ~ 75
Application area
(cooling standard)
Sq. ft. 172~300

Important Notes:

  1. Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
  2. Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
  3. Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.