Sale!
YMGI WMMS-12K-V2A(58)2
$2,648.00 $1,099.99
Description
Series (58)-16 to 22 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control, with Installation Kit), 115/1/60
Indoor Unit Model: WMMS-09E-V2A(58)2
Outdoor Unit Model: WMMS-09C-V2A(58)2
DC Inverter 22 SEER, 9,000 Btu/h, 115/1/60
System Model | WMMS-12K-V2A/B(58)2 | ||
Functions | COOLING | HEATING | |
Power Source | A:115/1/60 B:208~230/1/60 | ||
Nominal heating capacity (ID 70/60 OD 47/43F) | 13000 | ||
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD17/15F) | 11000 | ||
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD 5F) | 8900 | ||
Frequency(Hz) (High/Standard/Low) | 80/57/15 | 75/65/15 | |
Power Input (W) (High/ Standard/Low) | 1450/1000/120 | 1500/1200/220 | |
Rated Current (A) (High/ Standard) | A:14.5/7.5 B:6.8/3.5 | A:14.5/11 B:7.0/5.2 | |
SEER / HSPF (Btu/h.w) | 20 | 9.6 | |
EER (Btu/h.w) | 12.5 | ||
Dehumidifying Volume (Pints/Hr.) | 2.5 | ||
Indoor Unit (IDU) | Model of Indoor Unit | WMMS-12E-V2A/B(58)2 | |
Fan Motor Speed (RPM) (SH/H/M/L) | 1300/1080/900/740 | 1300/1160/1040/920 | |
Air Flow Volume (CFM) (SH/H/M/L) | 330/295/253/218 | ||
Output of Fan Motor (w) | 20 | ||
Input of Heater (w) | / | ||
Fan Motor Capacitor (uF) | 4.0 / 1.0 | ||
Fan Motor RLA(A) | 0.38 / 0.20 | ||
Fan Type-Piece | Cross flow fan-1 | ||
Fan Wheel Diameter-Length (In) | 3.6 x 25.4 | ||
Evaporator Coil Type | Aluminum fin-copper tube | ||
Coil-Copper Pipe Diameter (In) | 0.28 | ||
Row-FPI | 2-18.2 | ||
Coil length (L) x Height (H) x depth (D) (In) | 25.4x1x10.5 | ||
Swing Motor Model | MP24AA | ||
Output of Swing Motor (W) | 2.4 | ||
Fuse (A) | PCB 3.15A | ||
Sound Pressure Level dB (A) (SH/H/M/L) | 40/36/32/26 | ||
Sound Power Level dB (A) (SH/H/M/L) | 50/46/42/36 | ||
Outdoor Unit(ODU) | Model of Outdoor Unit | WMMS-12C-V2A/B(58)2 | |
Compressor Manufacturer | Sanyo, Mitisubishi or Equivalent | ||
Compressor Model | C-6RZ110H1A | ||
Compressor Type | Twin Rotary DC | ||
L.R.A. (A) | 33 | ||
Compressor RLA(A) | 4.59 | ||
Compressor Power Input(W) | 800 | ||
Overload Protector | 1NT11L-3979 | ||
Throttling Method | Electronic Expansion Valve | ||
Fuse Circuit Breaker of HVAC Type | A:30 B:20 | ||
Starting Method | Transducer starting | ||
Recommended Working Ambient Temp Range (°F) | 15°F ≤ T ≤115 °F | 5°F ≤ T ≤86 °F | |
Condenser Coil Type | Aluminum fin-copper tube | ||
Coil-Copper Pipe Diameter (In) | 0.35 | ||
Rows-FPI | 2-18.2 | ||
Coil Length (L) x Height (H) x Depth (D) (In) | 29.4X20X1.7 | ||
Fan Motor Speed (rpm) (H/L) | 900/680 | 900±20 | |
Output of Fan Motor (W) | 40 | ||
Fan Motor RLA (A) | 0.17 | ||
Fan Motor Capacitor (uF) | (DC) | ||
Air Flow Volume of Outdoor Unit CFM | 1120 | ||
Fan Type-Piece | Axial-1 | ||
Fan Diameter (In) | 15.7 | ||
Defrosting Type | Auto defrost | ||
Designed for Climate Type | T1 | ||
Isolation | I | ||
Moisture Protection | IP24 | ||
MAX. Operating Pressure for the Discharge Side (PSIG) | 551 | ||
MAX. Operating Pressure for the Suction Side (PSIG) | 174 | ||
Sound Pressure Level dB (A) (H/M/L) | ≤55 | ||
Sound Power Level dB (A) (H/M/L) | ≤65 | ||
Connection Pipe (In) | Outer Diameter Liquid Pipe (In) | 1/4 | |
Outer Diameter Gas Pipe (In) | 3/8 | ||
Max Distance ID Above/Blow OD (Ft.) | 35/45 | ||
Max Distance Length (Ft.) | 75 | ||
If Not Marked on Nameplate, Refrigerant Pre-charged for Copper Line Length | 25 | ||
Check Pressure at Trial Running Add or Deduct Refrigerant | 0.32 | ||
Dim. & Weight- Indoor Unit | Dimensions-Net W x H x D (Inches) | 33.4 x 21.3 x 12.6 | |
Dimensions of Carton Box W x H x D (Inches) | 36.0 x 14.0 x 10.0 | ||
Gross / Net Weight (LBs) | 31/24 | ||
Dim. & Weight- Outdoor Unit | Dimensions-Net W x H x D (Inches) | 33.4 x 21.3 x 12.6 | |
Dimensions of Carton Box W x H x D (Inches) | 34.6 x 22.8 x 14.2 | ||
Gross / Net Weight (LBs) | 97/88 | ||
Container Loading | Assumed-One Model/Container Sets (20’/40’/40’HQ) | 109/232/252 | |
Certification | Safety Approval (Third Party) | ETL (C & US) | |
Performance Approval (Third Party) | AHRI |
Important Notes:
- Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
- Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
- Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.