YMGI WMMS-18K-V2B(57)3 M1
$1,100.00
Single Zone 16 SEER
Line Sets/Wires Not Included
Description
Series (57)-16 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Indoor Unit Model: WMMS-18E-V2B(57)3
Outdoor Unit Model: WMMS-18C-V2B(57)3
DC Inverter 16 SEER, 18,000 Btu/h, 208-230/1/60
Indoor Unit | WMMS-18E-V2B(57)3 | |||
Outdoor Unit | WMMS-18C-V2B(57)3 | |||
Power supply | V/Ph/Hz | 208-230V/1/60Hz | ||
Cooling | Nominal Capacity | Btu/h | 18000 | |
Input | W | 1700 | ||
Rated current | Amp. | 7.4 | ||
EER | Btu/h.w | 9.7 | ||
SEER | Btu/h.w | 16.0 | ||
Heating | Capacity | Btu/h | 18000 | |
Input | W | 1600 | ||
Rated current | Amp. | 7.1 | ||
COP | W/W | 3.20 | ||
HSPF | Btu/h-w | 8.50 | ||
Minimum Circuit Ampacity | Amp. | 15 | ||
MAX HVAC Type Circuit Breaker |
Amp. | 20 | ||
Compressor | Model | ATD141RDPA8JT | ||
Type | Rotary | |||
Brand | HIGHLY | |||
Capacity | Btu/h | 5560 | ||
Input | W | 1255 | ||
Rated current(RLA) | Amp. | 4.2 | ||
Refrigerant oil/oil charge | ml | α68HES-H or equivalent 480±20ml |
||
Indoor fan motor | Model | YDK-50C-4P 3 A050501000360-R0 | ||
Brand | CG | |||
Input | W | 54 | ||
RLA | Amp. | 0.22 | ||
LRA | Amp. | 0.41 | ||
Winding Resistance | Ω | 203/169 | ||
Capacitor | uF | 1.8 | ||
Speed (Hi/Me/Lo) |
rpm | 1300±20 1150±20 1000±20 |
||
Indoor air flow (Hi/Me/Lo) | CFM | 471 / 417 / 362 | ||
Indoor noise level (Hi/Me/Lo) |
dB(A) | 47 | ||
Indoor unit | Dimension (WxDxH) | Inch | 35x11x8 | |
Packing WxDxH) | Inch | 39x15x12 | ||
Net/Gross weight |
lbs. | 29/33 | ||
Outdoor fan motor | Model | YDK-40-6C 1 H3 A050501000238-R0 | ||
Brand | CG | |||
Input | W | 85 | ||
RLA | Amp. | 0.37 | ||
LRA | Amp. | 0.60 | ||
Winding Resistance | Ω | 107/100.8 | ||
Capacitor | uF | 3 | ||
Speed | Rpm/M | 670 /870 | ||
Outdoor air flow | CFM | 1159 / 1200 | ||
Outdoor noise level | dB(A) | 53 / 41 | ||
Outdoor unit | Dimensions (WxDxH) | Inch | 33.46” x 11.49” x 23.85” | |
Packing (WxDxH) | Inch | 39x16x27 | ||
Net/Gross weight | lbs. | 88/99 | ||
R410A Refrigerant charge | Oz | 45.92 | ||
Refrigerant precharge maximum pipe length | Ft. | 25 | ||
Additional charge for each ft. | Oz | 0.23 | ||
Design pressure | PSIG | 510/250 | ||
Refrigerant piping | Liquid side/ Gas side |
Inch | 1/4″+1/2″ | |
Max. refrigerant pipe length | Ft. | 49.2 | ||
Max. difference in level | Ft. | 16.4 | ||
Connection wires between IDU and ODU | 4×AWG18 | |||
Control Type | Remote Control | |||
Operation Temperature Ranges | Indoor (cooling/ heating) | °F | 61~90 | |
Outdoor (cooling / heating) |
°F | AC: 15~115 / HP: -4 ~ 75 |
||
Application area (cooling standard) |
Sq. ft. | 258~450 |
Important Notes:
- Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
- Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
- Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.