YMGI WMMS-18K-V2B(58)2
$1,840.00
Description
Series (58)-16 to 22 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Line Sets/Wires Not Included
Indoor Unit Model: WMMS-18E-V2B(58)2
Outdoor Unit Model: WMMS-18C-V2B(58)2
DC Inverter 18 SEER, 18,000 Btu/h, 208-230/1/60
System Model | WMMS-18K-V2B(58)2 | ||
Functions | COOLING | HEATING | |
Power Source | 208~230/1/60 | ||
Nominal heating capacity (ID 70/60 OD 47/43F) | 25000 | ||
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD17/15F) | 16400 | ||
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD 5F) | 14500 | ||
Frequency(Hz) (High/Standard/Low) | 100/60/15 | ||
Power Input (W) (High/ Standard/Low) | 2500/1500/300 | 2550/1600/335 | |
Rated Current (A) (High/ Standard) | A:15.5/12.5 B:7.5/6.0 | 12.0/7.5 12.56/7.7 | |
SEER / HSPF (Btu/h.w) | 18.0 | 10.2 | |
EER (Btu/h.w) | 12 | ||
Dehumidifying Volume (Pints/Hr.) | 4.2 | ||
Indoor Unit (IDU) | Model of Indoor Unit | WMMS-18E-V2B(58)2 | |
Fan Motor Speed (RPM) (SH/H/M/L) | 1350/1200/1050/900 | 1420/1250/1150/1050 | |
Air Flow Volume (CFM) (SH/H/M/L) | 500/460/383/324 | ||
Output of Fan Motor (w) | 20 | ||
Input of Heater (w) | / | ||
Fan Motor Capacitor (uF) | 1.5 | ||
Fan Motor RLA(A) | 0.25 | ||
Fan Type-Piece | Cross flow fan-1 | ||
Fan Wheel Diameter-Length (In) | 3.9 x 28.0 | ||
Evaporator Coil Type | Aluminum fin-copper tube | ||
Coil-Copper Pipe Diameter (In) | 0.28 | ||
Row-FPI | 2-18.2 | ||
Coil length (L) x Height (H) x depth (D) (In) | 28.1x12x1 | ||
Swing Motor Model | MP28VB | ||
Output of Swing Motor (W) | 2.5 | ||
Fuse (A) | PCB 3.15A Transformer 0.2A | ||
Sound Pressure Level dB (A) (SH/H/M/L) | 46/44/40/35 | ||
Sound Power Level dB (A) (SH/H/M/L) | 56/54/50/45 | ||
Outdoor Unit(ODU) | Model of Outdoor Unit | WMMS-18C-V2B(58)2 | |
Compressor Manufacturer | Sanyo, Mitisubishi or Equivalent | ||
Compressor Model | C-6RZ146H1A | ||
Compressor Type | Twin Rotary DC | ||
L.R.A. (A) | 41 | ||
Compressor RLA(A) | 8.4 | ||
Compressor Power Input(W) | 1640 | ||
Overload Protector | 1NT11L-3979 | ||
Throttling Method | Electronic Expansion Valve | ||
Fuse Circuit Breaker of HVAC Type | 20 | ||
Starting Method | Transducer starting | ||
Recommended Working Ambient Temp Range (°F) | 15°F ≤ T ≤115 °F | 5°F ≤ T ≤86 °F | |
Condenser Coil Type | Aluminum fin-copper tube | ||
Coil-Copper Pipe Diameter (In) | 0.28 | ||
Rows-FPI | 2-18.2 | ||
Coil Length (L) x Height (H) x Depth (D) (In) | 33.0×26.0x1.5 | ||
Fan Motor Speed (rpm) (H/L) | 690/500 | ||
Output of Fan Motor (W) | 60 | ||
Fan Motor RLA (A) | 0.62 | ||
Fan Motor Capacitor (uF) | 3 | ||
Air Flow Volume of Outdoor Unit CFM | 1890 | ||
Fan Type-Piece | Axial-1 | ||
Fan Diameter (In) | 20.5 | ||
Defrosting Type | Auto defrost | ||
Designed for Climate Type | T1 | ||
Isolation | I | ||
Moisture Protection | IP24 | ||
MAX. Operating Pressure for the Discharge Side (PSIG) | 551 | ||
MAX. Operating Pressure for the Suction Side (PSIG) | 174 | ||
Sound Pressure Level dB (A) (H/M/L) | 54 | ||
Sound Power Level dB (A) (H/M/L) | 64 | ||
Connection Pipe (In) | Outer Diameter Liquid Pipe (In) | 1/4 | |
Outer Diameter Gas Pipe (In) | 1/2 | ||
Max Distance ID Above/Blow OD (Ft.) | 50/60 | ||
Max Distance Length (Ft.) | 100 | ||
If Not Marked on Nameplate, Refrigerant Pre-charged for Copper Line Length | 25 | ||
Check Pressure at Trial Running Add or Deduct Refrigerant | 0.32 | ||
Dim. & Weight- Indoor Unit | Dimensions-Net W x H x D (Inches) | 37.0 X 11.7 X 7.9 | |
Dimensions of Carton Box W x H x D (Inches) | 39.8 X 15.0 X 11.2 | ||
Gross / Net Weight (LBs) | 37.5/28.7 | ||
Dim. & Weight- Outdoor Unit | Dimensions-Net W x H x D (Inches) | 35.0 X 27.6 X 13.4 | |
Dimensions of Carton Box W x H x D (Inches) | 40.6 X 28.9 X 18.1 | ||
Gross / Net Weight (LBs) | 121/110 | ||
Container Loading | Assumed-One Model/Container Sets (20’/40’/40’HQ) | 60/125/145 | |
Certification | Safety Approval (Third Party) | ETL (C & US) | |
Performance Approval (Third Party) | AHRI |
Important Notes:
- Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
- Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
- Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.