YMGI WMMS-24K-V2B(57)3 M1

$1,500.00

Single Zone 16 SEER
Line Sets/Wires Not Included

Description

Series (57)-16 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)

Indoor Unit Model: WMMS-24E-V2B(57)3
Outdoor Unit Model: WMMS-24C-V2B(57)3

DC Inverter 16 SEER, 24,000 Btu/h, 208-230/1/60

Indoor Unit WMMS-24E-V2B(57)3
Outdoor Unit WMMS-24C-V2B(57)3
Power supply V/Ph/Hz 208-230V/1/60Hz
Cooling Nominal Capacity Btu/h 22000
Input W 2310
Rated current Amp. 10.1
EER Btu/h.w 9.35
SEER Btu/h.w 15.0
Heating Capacity Btu/h 22000
Input W 2230
Rated current Amp. 9.7
COP W/W 3.20
HSPF Btu/h-w 8.50
Minimum Circuit Ampacity Amp. 20
MAX HVAC Type
Circuit Breaker
Amp. 30
Compressor Model ATD186UKQA9LT6
Type Rotary
Brand HIGHLY
Capacity Btu/h 7200
Input W 1610
Rated current(RLA) Amp. 4.8
Refrigerant oil/oil charge ml α68HES-H or
equivalent
770±20ml
Indoor fan motor Model YDK-50C-4P 1 A050501000342-R0
Brand CG
Input W 70
RLA Amp. 0.31
LRA Amp. 0.42
Winding Resistance Ω 174/138.8
Capacitor uF 2
Speed
(Hi/Me/Lo)
rpm 1350±20
1200±20
1050±20
Indoor air flow (Hi/Me/Lo) CFM 588 / 524 / 459
Indoor
noise level (Hi/Me/Lo)
dB(A) 49
Indoor unit Dimension (WxDxH) Inch 43x12x9
Packing WxDxH) Inch 46x15x12
Net/Gross
weight
lbs. 33/37
Outdoor fan motor Model YDK-60B-6C 030020236R
Brand CG
Input W 156
RLA Amp. 0.68
LRA Amp. 0.89
Winding Resistance Ω 66.2/69.4
Capacitor uF 4
Speed Rpm/M 780±20
Outdoor air flow CFM 2000 / 1538
Outdoor noise level dB(A) 58 / 43
Outdoor unit Dimensions (WxDxH) Inch 35.82” x 13.38” x 27.51”
Packing (WxDxH) Inch 41.73×18.1×37.1
Net/Gross weight lbs. 114/127
R410A Refrigerant charge Oz 68.68
Refrigerant precharge maximum pipe length Ft. 25
Additional charge for each ft. Oz 0.23
Design pressure PSIG 510/250
Refrigerant piping Liquid side/
Gas side
Inch 3/8”+5/8″
Max. refrigerant pipe length Ft. 49.2
Max. difference in level Ft. 16.4
Connection wires between
IDU and ODU
4×AWG18
Control Type Remote Control
Operation Temperature Ranges Indoor (cooling/ heating) °F 61~90
Outdoor
(cooling / heating)
°F AC: 15~115 /
HP: -4 ~ 75
Application area
(cooling standard)
Sq. ft. 344~600

Important Notes:

  1. Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
  2. Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
  3. Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.