YMGI WMMS-24K-V2B(57)3 M1
$1,500.00
Single Zone 16 SEER
Line Sets/Wires Not Included
Description
Series (57)-16 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Indoor Unit Model: WMMS-24E-V2B(57)3
Outdoor Unit Model: WMMS-24C-V2B(57)3
DC Inverter 16 SEER, 24,000 Btu/h, 208-230/1/60
Indoor Unit | WMMS-24E-V2B(57)3 | |||
Outdoor Unit | WMMS-24C-V2B(57)3 | |||
Power supply | V/Ph/Hz | 208-230V/1/60Hz | ||
Cooling | Nominal Capacity | Btu/h | 22000 | |
Input | W | 2310 | ||
Rated current | Amp. | 10.1 | ||
EER | Btu/h.w | 9.35 | ||
SEER | Btu/h.w | 15.0 | ||
Heating | Capacity | Btu/h | 22000 | |
Input | W | 2230 | ||
Rated current | Amp. | 9.7 | ||
COP | W/W | 3.20 | ||
HSPF | Btu/h-w | 8.50 | ||
Minimum Circuit Ampacity | Amp. | 20 | ||
MAX HVAC Type Circuit Breaker |
Amp. | 30 | ||
Compressor | Model | ATD186UKQA9LT6 | ||
Type | Rotary | |||
Brand | HIGHLY | |||
Capacity | Btu/h | 7200 | ||
Input | W | 1610 | ||
Rated current(RLA) | Amp. | 4.8 | ||
Refrigerant oil/oil charge | ml | α68HES-H or equivalent 770±20ml |
||
Indoor fan motor | Model | YDK-50C-4P 1 A050501000342-R0 | ||
Brand | CG | |||
Input | W | 70 | ||
RLA | Amp. | 0.31 | ||
LRA | Amp. | 0.42 | ||
Winding Resistance | Ω | 174/138.8 | ||
Capacitor | uF | 2 | ||
Speed (Hi/Me/Lo) |
rpm | 1350±20 1200±20 1050±20 |
||
Indoor air flow (Hi/Me/Lo) | CFM | 588 / 524 / 459 | ||
Indoor noise level (Hi/Me/Lo) |
dB(A) | 49 | ||
Indoor unit | Dimension (WxDxH) | Inch | 43x12x9 | |
Packing WxDxH) | Inch | 46x15x12 | ||
Net/Gross weight |
lbs. | 33/37 | ||
Outdoor fan motor | Model | YDK-60B-6C 030020236R | ||
Brand | CG | |||
Input | W | 156 | ||
RLA | Amp. | 0.68 | ||
LRA | Amp. | 0.89 | ||
Winding Resistance | Ω | 66.2/69.4 | ||
Capacitor | uF | 4 | ||
Speed | Rpm/M | 780±20 | ||
Outdoor air flow | CFM | 2000 / 1538 | ||
Outdoor noise level | dB(A) | 58 / 43 | ||
Outdoor unit | Dimensions (WxDxH) | Inch | 35.82” x 13.38” x 27.51” | |
Packing (WxDxH) | Inch | 41.73×18.1×37.1 | ||
Net/Gross weight | lbs. | 114/127 | ||
R410A Refrigerant charge | Oz | 68.68 | ||
Refrigerant precharge maximum pipe length | Ft. | 25 | ||
Additional charge for each ft. | Oz | 0.23 | ||
Design pressure | PSIG | 510/250 | ||
Refrigerant piping | Liquid side/ Gas side |
Inch | 3/8”+5/8″ | |
Max. refrigerant pipe length | Ft. | 49.2 | ||
Max. difference in level | Ft. | 16.4 | ||
Connection wires between IDU and ODU |
4×AWG18 | |||
Control Type | Remote Control | |||
Operation Temperature Ranges | Indoor (cooling/ heating) | °F | 61~90 | |
Outdoor (cooling / heating) |
°F | AC: 15~115 / HP: -4 ~ 75 |
||
Application area (cooling standard) |
Sq. ft. | 344~600 |
Important Notes:
- Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
- Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
- Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.