YMGI WMMS-24K-V2B(58)4

$2,070.00

Series (58)-16 to 22 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control, with Installation Kit)

Indoor Unit Model: WMMS-24E-V2B(58)2
Outdoor Unit Model: WMMS-24C-V2B(58)2

DC Inverter 18 SEER, 24,000 Btu/h, 208-230/1/60

Out of stock

Description

Series (58)-16 to 22 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Line Sets/Wires Not Included

Indoor Unit Model: WMMS-24E-V2B(58)4
Outdoor Unit Model: WMMS-24C-V2B(58)4

DC Inverter 18 SEER, 24,000 Btu/h, 208-230/1/60

 

System Model WMMS-24K-V2B(58)2
Functions COOLING HEATING
Power Source 208~230/1/60
Nominal heating capacity (ID 70/60 OD 47/43F) 26000
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD17/15F) 17800
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD 5F) 15400
Frequency(Hz) (High/Standard/Low) 100/60/15
Power Input (W) (High/ Standard/Low) 2650/1700/400 2750/1790/500
Rated Current (A) (High/ Standard) 12.7/8.2 13.2/8.6
SEER / HSPF (Btu/h.w) 18.0 10.2
EER (Btu/h.w) 12
Dehumidifying Volume (Pints/Hr.) 5.5
Indoor Unit (IDU) Model of Indoor Unit WMMS-24E-V2B(58)2
Fan Motor Speed (RPM) (SH/H/M/L) 1400/1150/1100/850 1400/1150/1100/900
Air Flow Volume (CFM) (SH/H/M/L) 560/471/412/353
Output of Fan Motor (w) 35
Input of Heater (w) /
Fan Motor Capacitor (uF) 2.5
Fan Motor RLA(A) 0.45
Fan Type-Piece Cross flow fan-1
Fan Wheel Diameter-Length (In) 3.9 x 30.1
Evaporator Coil Type Aluminum fin-copper tube
Coil-Copper Pipe Diameter (In) 0.28
Row-FPI 2-16.9
Coil length (L) x Height (H) x depth (D) (In) 30.1×13.5×1
Swing Motor Model MP35XX
Output of Swing Motor (W) 2.5
Fuse (A) PCB 3.15A Transformer 0.2A
Sound Pressure Level dB (A) (SH/H/M/L) 48/44/40/35
Sound Power Level dB (A) (SH/H/M/L) 58/54/50/45
Outdoor Unit(ODU) Model of Outdoor Unit WMMS-24C-V2B(58)2
Compressor Manufacturer Sanyo, Mitisubishi or Equivalent
Compressor Model C-6RZ146H1A
Compressor Type Twin Rotary DC
L.R.A. (A) 41
Compressor RLA(A) 8.4
Compressor Power Input(W) 1640
Overload Protector 1NT11L-3979
Throttling Method Electronic Expansion Valve
Fuse Circuit Breaker of HVAC Type 30
Starting Method Transducer starting
Recommended Working Ambient Temp Range (°F) 15°F ≤ T ≤115 °F 5°F ≤ T ≤86 °F
Condenser Coil Type Aluminum fin-copper tube
Coil-Copper Pipe Diameter (In) 0.28
Rows-FPI 2-18.2
Coil Length (L) x Height (H) x Depth (D) (In) 38.1×29.4×1.5
Fan Motor Speed (rpm) (H/L) 780/500
Output of Fan Motor (W) 90
Fan Motor RLA (A) 0.90
Fan Motor Capacitor (uF) 4
Air Flow Volume of Outdoor Unit CFM 2480
Fan Type-Piece Axial-1
Fan Diameter (In) 21.7
Defrosting Type Auto defrost
Designed for Climate Type T1
Isolation I
Moisture Protection IP24
MAX. Operating Pressure for the Discharge Side (PSIG) 551
MAX. Operating Pressure for the Suction Side (PSIG) 174
Sound Pressure Level dB (A) (H/M/L) 56
Sound Power Level dB (A) (H/M/L) 66
Connection Pipe (In) Outer Diameter Liquid Pipe (In) 1/4
Outer Diameter Gas Pipe (In) 5/8
Max Distance ID Above/Blow OD (Ft.) 50/60
Max Distance Length (Ft.) 100
If Not Marked on Nameplate, Refrigerant Pre-charged for Copper Line Length 25
Check Pressure at Trial Running Add or Deduct Refrigerant 0.38
Dim. & Weight- Indoor Unit Dimensions-Net W x H x D (Inches) 39.7 X 12.4 X 8.6
Dimensions of Carton Box W x H x D (Inches) 42.2 X 15.6 X 12.3
Gross / Net Weight (LBs) 46.3/35.3
Dim. & Weight- Outdoor Unit Dimensions-Net W x H x D (Inches) 36.2 X 31.1 X 14.6
Dimensions of Carton Box W x H x D (Inches) 41.9 X 33.1 X 19.0
Gross / Net Weight (LBs) 132/119
Container Loading Assumed-One Model/Container Sets (20’/40’/40’HQ) 47/96/114
Certification Safety Approval (Third Party) ETL (C & US)
Performance Approval (Third Party) AHRI

Important Notes:

  1. Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
  2. Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
  3. Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.