YMGI WMMS-24K-V2B(58)4
$2,070.00
Series (58)-16 to 22 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control, with Installation Kit)
Indoor Unit Model: WMMS-24E-V2B(58)2
Outdoor Unit Model: WMMS-24C-V2B(58)2
DC Inverter 18 SEER, 24,000 Btu/h, 208-230/1/60
Out of stock
Description
Series (58)-16 to 22 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Line Sets/Wires Not Included
Indoor Unit Model: WMMS-24E-V2B(58)4
Outdoor Unit Model: WMMS-24C-V2B(58)4
DC Inverter 18 SEER, 24,000 Btu/h, 208-230/1/60
System Model | WMMS-24K-V2B(58)2 | ||
Functions | COOLING | HEATING | |
Power Source | 208~230/1/60 | ||
Nominal heating capacity (ID 70/60 OD 47/43F) | 26000 | ||
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD17/15F) | 17800 | ||
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD 5F) | 15400 | ||
Frequency(Hz) (High/Standard/Low) | 100/60/15 | ||
Power Input (W) (High/ Standard/Low) | 2650/1700/400 | 2750/1790/500 | |
Rated Current (A) (High/ Standard) | 12.7/8.2 | 13.2/8.6 | |
SEER / HSPF (Btu/h.w) | 18.0 | 10.2 | |
EER (Btu/h.w) | 12 | ||
Dehumidifying Volume (Pints/Hr.) | 5.5 | ||
Indoor Unit (IDU) | Model of Indoor Unit | WMMS-24E-V2B(58)2 | |
Fan Motor Speed (RPM) (SH/H/M/L) | 1400/1150/1100/850 | 1400/1150/1100/900 | |
Air Flow Volume (CFM) (SH/H/M/L) | 560/471/412/353 | ||
Output of Fan Motor (w) | 35 | ||
Input of Heater (w) | / | ||
Fan Motor Capacitor (uF) | 2.5 | ||
Fan Motor RLA(A) | 0.45 | ||
Fan Type-Piece | Cross flow fan-1 | ||
Fan Wheel Diameter-Length (In) | 3.9 x 30.1 | ||
Evaporator Coil Type | Aluminum fin-copper tube | ||
Coil-Copper Pipe Diameter (In) | 0.28 | ||
Row-FPI | 2-16.9 | ||
Coil length (L) x Height (H) x depth (D) (In) | 30.1×13.5×1 | ||
Swing Motor Model | MP35XX | ||
Output of Swing Motor (W) | 2.5 | ||
Fuse (A) | PCB 3.15A Transformer 0.2A | ||
Sound Pressure Level dB (A) (SH/H/M/L) | 48/44/40/35 | ||
Sound Power Level dB (A) (SH/H/M/L) | 58/54/50/45 | ||
Outdoor Unit(ODU) | Model of Outdoor Unit | WMMS-24C-V2B(58)2 | |
Compressor Manufacturer | Sanyo, Mitisubishi or Equivalent | ||
Compressor Model | C-6RZ146H1A | ||
Compressor Type | Twin Rotary DC | ||
L.R.A. (A) | 41 | ||
Compressor RLA(A) | 8.4 | ||
Compressor Power Input(W) | 1640 | ||
Overload Protector | 1NT11L-3979 | ||
Throttling Method | Electronic Expansion Valve | ||
Fuse Circuit Breaker of HVAC Type | 30 | ||
Starting Method | Transducer starting | ||
Recommended Working Ambient Temp Range (°F) | 15°F ≤ T ≤115 °F | 5°F ≤ T ≤86 °F | |
Condenser Coil Type | Aluminum fin-copper tube | ||
Coil-Copper Pipe Diameter (In) | 0.28 | ||
Rows-FPI | 2-18.2 | ||
Coil Length (L) x Height (H) x Depth (D) (In) | 38.1×29.4×1.5 | ||
Fan Motor Speed (rpm) (H/L) | 780/500 | ||
Output of Fan Motor (W) | 90 | ||
Fan Motor RLA (A) | 0.90 | ||
Fan Motor Capacitor (uF) | 4 | ||
Air Flow Volume of Outdoor Unit CFM | 2480 | ||
Fan Type-Piece | Axial-1 | ||
Fan Diameter (In) | 21.7 | ||
Defrosting Type | Auto defrost | ||
Designed for Climate Type | T1 | ||
Isolation | I | ||
Moisture Protection | IP24 | ||
MAX. Operating Pressure for the Discharge Side (PSIG) | 551 | ||
MAX. Operating Pressure for the Suction Side (PSIG) | 174 | ||
Sound Pressure Level dB (A) (H/M/L) | 56 | ||
Sound Power Level dB (A) (H/M/L) | 66 | ||
Connection Pipe (In) | Outer Diameter Liquid Pipe (In) | 1/4 | |
Outer Diameter Gas Pipe (In) | 5/8 | ||
Max Distance ID Above/Blow OD (Ft.) | 50/60 | ||
Max Distance Length (Ft.) | 100 | ||
If Not Marked on Nameplate, Refrigerant Pre-charged for Copper Line Length | 25 | ||
Check Pressure at Trial Running Add or Deduct Refrigerant | 0.38 | ||
Dim. & Weight- Indoor Unit | Dimensions-Net W x H x D (Inches) | 39.7 X 12.4 X 8.6 | |
Dimensions of Carton Box W x H x D (Inches) | 42.2 X 15.6 X 12.3 | ||
Gross / Net Weight (LBs) | 46.3/35.3 | ||
Dim. & Weight- Outdoor Unit | Dimensions-Net W x H x D (Inches) | 36.2 X 31.1 X 14.6 | |
Dimensions of Carton Box W x H x D (Inches) | 41.9 X 33.1 X 19.0 | ||
Gross / Net Weight (LBs) | 132/119 | ||
Container Loading | Assumed-One Model/Container Sets (20’/40’/40’HQ) | 47/96/114 | |
Certification | Safety Approval (Third Party) | ETL (C & US) | |
Performance Approval (Third Party) | AHRI |
Important Notes:
- Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
- Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
- Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.