YMGI WMMS-36K-V2B(58)4
$2,700.00
Description
Series (58)-16 to 22 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Line Sets/Wires Not Included
Indoor Unit Model: WMMS-36E-V2B(58)2
Outdoor Unit Model: WMMS-36C-V2B(58)2
DC Inverter 16 SEER, 36,000 Btu/h, 208-230/1/60
| System Model | WMMS-36K-V2B(58)2 | ||
| Functions | COOLING | HEATING | |
| Power Source | 208~230/1/60 | ||
| Nominal heating capacity (ID 70/60 OD 47/43F) | 34600 | ||
| Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD17/15F) | 31600 | ||
| Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD 5F) | 26800 | ||
| Frequency(Hz) (High/Standard/Low) | 100/60/15 | ||
| Power Input (W) (High/ Standard/Low) | 3800/3650/610 | 3700/3560/970 | |
| Rated Current (A) (High/ Standard) | 18.2/15.1 | 18.2/15.5 | |
| SEER / HSPF (Btu/h.w) | 16 | 8.2 | |
| EER (Btu/h.w) | 9.2 | ||
| Dehumidifying Volume (Pints/Hr.) | 7.4 | ||
| Indoor Unit (IDU) | Model of Indoor Unit | WMMS-36E-V2B(58)2 | |
| Fan Motor Speed (RPM) (SH/H/M/L) | 1400/1300/1200/1000 | 1400/1300/1200/1000 | |
| Air Flow Volume (CFM) (SH/H/M/L) | 740/670/640/580 | ||
| Output of Fan Motor (w) | 40 | ||
| Input of Heater (w) | / | ||
| Fan Motor Capacitor (uF) | 3.5 | ||
| Fan Motor RLA(A) | 0.4 | ||
| Fan Type-Piece | Cross flow fan-1 | ||
| Fan Wheel Diameter-Length (In) | 4.25 x 41.0 | ||
| Evaporator Coil Type | Aluminum fin-copper tube | ||
| Coil-Copper Pipe Diameter (In) | 0.28 | ||
| Row-FPI | 2-19 | ||
| Coil length (L) x Height (H) x depth (D) (In) | 42.25x15x1 | ||
| Swing Motor Model | MP24BA | ||
| Output of Swing Motor (W) | 2 | ||
| Fuse (A) | PCB 3.15A Transformer 0.2A | ||
| Sound Pressure Level dB (A) (SH/H/M/L) | 52/50/48/40 | ||
| Sound Power Level dB (A) (SH/H/M/L) | 62/60/58/50 | ||
| Outdoor Unit(ODU) | Model of Outdoor Unit | WMMS-36C-V2B(58)2 | |
| Compressor Manufacturer | Mitisubishi or Equivalent | ||
| Compressor Model | TNB306FPGM | ||
| Compressor Type | Rotary DC | ||
| L.R.A. (A) | 67 | ||
| Compressor RLA(A) | 13.5 | ||
| Compressor Power Input(W) | 3010 | ||
| Overload Protector | CS01F272H01 | ||
| Throttling Method | Capillary | ||
| Fuse Circuit Breaker of HVAC Type | 40 | ||
| Starting Method | Transducer starting | ||
| Recommended Working Ambient Temp Range (°F) | 15°F ≤ T ≤115 °F | 5°F ≤ T ≤86 °F | |
| Condenser Coil Type | Aluminum fin-copper tube | ||
| Coil-Copper Pipe Diameter (In) | 3/8 | ||
| Rows-FPI | 2-1.4 | ||
| Coil Length (L) x Height (H) x Depth (D) (In) | 37.0×30.0x1.7 | ||
| Fan Motor Speed (rpm) (H/L) | 830 | ||
| Output of Fan Motor (W) | 120 | ||
| Fan Motor RLA (A) | 0.45 | ||
| Fan Motor Capacitor (uF) | 5 | ||
| Air Flow Volume of Outdoor Unit CFM | 2860 | ||
| Fan Type-Piece | Axial-1 | ||
| Fan Diameter (In) | 21.7 | ||
| Defrosting Type | Auto defrost | ||
| Designed for Climate Type | T1 | ||
| Isolation | I | ||
| Moisture Protection | IP24 | ||
| MAX. Operating Pressure for the Discharge Side (PSIG) | 560 | ||
| MAX. Operating Pressure for the Suction Side (PSIG) | 170 | ||
| Sound Pressure Level dB (A) (H/M/L) | 59/-/57 | ||
| Sound Power Level dB (A) (H/M/L) | 69/-/67 | ||
| Connection Pipe (In) | Outer Diameter Liquid Pipe (In) | 1/4 | |
| Outer Diameter Gas Pipe (In) | 5/8 | ||
| Max Distance ID Above/Blow OD (Ft.) | 50/60 | ||
| Max Distance Length (Ft.) | 125 | ||
| If Not Marked on Nameplate, Refrigerant Pre-charged for Copper Line Length | 25 | ||
| Check Pressure at Trial Running Add or Deduct Refrigerant | 0.54 | ||
| Dim. & Weight- Indoor Unit | Dimensions-Net W x H x D (Inches) | 53.1 X 12.8 X 10.0 | |
| Dimensions of Carton Box W x H x D (Inches) | 56.6 X 16.5 X 13.5 | ||
| Gross / Net Weight (LBs) | 60/44 | ||
| Dim. & Weight- Outdoor Unit | Dimensions-Net W x H x D (Inches) | 38.5 X 31.3 X 16.8 | |
| Dimensions of Carton Box W x H x D (Inches) | 42.5 X 33.3 X 19.3 | ||
| Gross / Net Weight (LBs) | 170/161 | ||
| Container Loading | Assumed-One Model/Container Sets (20’/40’/40’HQ) | 36/75/92 | |
| Certification | Safety Approval (Third Party) | ETL (C & US) | |
| Performance Approval (Third Party) | AHRI | ||
Important Notes:
- Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
- Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
- Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.