YMGI WMMS-48CH-V2B(59)4 (5-Zone)
$2,830.00
DC Inverter 21SEER, Outdoor Unit-Quad Zone, up to 57K Btu/h
Description
- Zone (Indoor Unit Qty.): 2-5 Zones
- Allowed Indoor Unit Capacity Rating Total: up to 48,000 Btu/h
- Allowed Indoor Unit Max. Qty.: 5
- Required Indoor Unit Min. Qty. 2
Line Sets/ Wires not included
Description
DC Inverter 21SEER, Outdoor Unit-Quad Zone, up to 57K Btu/h
Description
- Zone (Indoor Unit Qty.): 2-5 Zones
- Allowed Indoor Unit Capacity Rating Total: up to 48,000 Btu/h
- Allowed Indoor Unit Max. Qty.: 5
- Required Indoor Unit Min. Qty. 2
YMGI Specifications: DC Inverter Mini Split Heat Pump-Multiple Zone-(59)4 Outdoor Units 21SEER | ||
Model | Units | WMMS-48CH-V2B(59)4 |
Cooling Capacity Rating-Standard Comp. Speed | Btu/h | 34000 |
Min./Max. Cooling Capacity | Btu/h | 8871 / 35826 |
Heating Capacity Rating-Standard Comp. Speed | Btu/h | 42500 |
Min./Max. Heating Capacity | Btu/h | 8871 / 44356 |
Max. Allowed IDU Qty./Capacity Total | # / Btu/h | 5 / 48,000 |
EER W/W, (Btu/h)/W | W/W | 3.66 / 12.5 |
COP W/W, (Btu/h)/W | W/W | 3.70 / 12.62 |
SEER / HSPF | – | 21.00 / 10.50 |
Air Flow Volume | CFM | 4531 |
Sound Pressure / Power Level | dB(A) | 61 / 71 |
Power Supply | V/Ph/Hz | 208-230/1/60 |
Power Cable Conductor Minimum Size | AWG | AWG10, Following NEC |
Recommended HVAC Type Circuit Breaker Size | Amp. | 40 |
Power Input Cooling / Heating / Rated | KW | 2.72 / 3.37 / 3.80 |
Current Input Cooling / Heating / Rated | A | 11.84 / 14.64 / 16.86 |
Compressor Type, Model | – | Inverter Rotarty, LD QXAS- D32zX090A |
Compressor Capacity / Input | W | 12300 / 4150 |
Compressor RLA / LRA | A | 15.6 / – |
Compressor Crankcase Heater | W | 40 |
Compressor Oil Type, Charge | -, OZs | FV50S, 35.2 |
De-Ice/Snow Heater Power Input | W | 96 |
De-Ice/Snow Heater Current | A | 0.4 |
Fan Type / Qty. / Diameter-Height | – | Axial-flow / 1 /D570-H152mm |
Motor Model / Type | – | SWZ150B, DC |
Motor Insulation Class, Safe Class | – | E, IPX4 |
Fan Motor Drive Type, Speed | – | Director Drive, 880 |
Fan Motor Power Output / Input | W | 170 / 240 |
Motor Full Load Amp (FLA) | A | 0.82 |
Condenser Materials | – | Aluminum Fin-Copper Tube |
Permissible Operating Pressure for the Discharge/Suction Sides | PSI | 600 / 360 |
High/Low Pressure Overload Protector | PSI | 580 / – |
Cooling Operation Ambient Temperature Range | F | 0 ~ 118 |
Heating Operation Ambient Temperature Range | F | -4 ~ 75 |
Defrosting Method of Heat Pump in Low Temperature Ambient |
— | Automatic Reversing, Fan Cycling |
Pressure Maitenance Method in Low Temperature Cooling |
— | Automatic Fan Speed Control, Cycling |
Overload Protector | – | Current+Temperature |
Designed for Climate Type, Moisture Protection | – | T1, IPX4 |
Refrigerant, Charge | LBs | R410A, 8.0 |
Metering Device KINGERSONS | – | Electronic expansion valve |
Flare/Nut Valve Size-Liquid | Inch | 1/4, 1/4, 1/4, 1/4, 1/4 |
Flare/Nut Valve Size-Gas | Inch | 3/8, 3/8, 3/8, 3/8, 3/8 |
Min. Allowed Copper Line Length/Unit | Ft. | 15 |
Max. Allowed Copper Line Length- outdoor to last indoor unit |
Ft. | 80 |
Max. Elevation Difference Allowed- outdoor unit is below all indoor units |
Ft. | 50, Oil Trap is Not Needed |
Max. Elevation Difference Allowed- outdoor unit is above indoor units |
Ft. | 50, Oil Trap is Suggested Every 25′ |
Max. Copper Line Length (all together) | Ft. | 246 |
No Additional Refrigerant Needs to be Added, If Copper Line Length Total is Less Than | Ft. | 150 |
Refrigerant Charge Rate, If Needed, by Weight/Ft. of Extra Liquid Line Length |
Ozs/Ft. | 2.32 |
Dimension of Unit Outline (W×D×H) | Inch | 42.8×17.3×43.4 |
Dimension of Package (W×D×H) | Inch | 45.6×19.4×48.6 |
Weight-Net / Gross | LBs | 198 / 216 |