YMGI 30,000 Btu (59) Series Console IDU Multi Zone Mini Split Systems (2 IDU)

$2,760.00

YMGI (59) Series DC Inverter Dual Zone-Outdoor Unit (59)4 is a 30k Btu system that runs quietly and efficiently for any two room application. The system comes with two 9k console indoor units that can be mounted to the floor or wall. This Dual Zone outdoor condensing unit has an 21 SEER rating. With heating and cooling capacities of 48k Btu that are powered by 208-230 volt, 1 phase, 60Hz. The compact outdoor unit allows for ground installation, or mounting in a variety of discreet locations, including on a wall, on a roof, under a deck or even on a balcony. Includes 2 x 25′ Copper Line sets and Wires, and Free Shipping

Out of stock

SKU: 2X09EL-WMMS-30CH-V2B(59)4 Categories: , , ,

Description

DC Inverter Mini System-Multiple Zone-(59)4 21 SEER
CHOIR Outdoor Units 2 Zone 30k Btu/h

Outdoor Unit Models WMMS-30CH-V2B(59)4
(1 to 2)
Power Supply 208-230/1/60
Cooling Capacity* (Btu/h) Max. IDU Cap.
Total 2
30,000
(2 Thermal Zones)
Rated 1 18,000
Min 7,000
Total Power Input in Cooling Mode* (W) Max. 2300
Rated 1550
Min. 650
SEER Btu/h 22.00
HSPF Btu/h 10.50
Heating Capacity* (Btu/h) Max. IDU Cap.
Total 2
32,000
Rated 1 19,000
Min. 7,000
Total Power Input in Heating Mode* Max. 2400
Rated 1750
Min. 650
Liquid Valve Size In 2 x 1/4”
Gas Valve Size In 2 x 3/8”
Compressor Oil RB68EP
L.R.A. A 27
Compressor RLA A 10.82
Compressor Power Input W 1440
MCA A 15
Fuse or Circuit Breaker (HVAC Type) A 25
Throttling Method Electronic Expansion Valve
Starting Method Transducer starting
Recommended Working
Ambient Temp Ranges
°F AC: 0 ~ 118
HP:-4 ~ 75
Condenser Aluminum fin-copper tube
Output of Fan Motor W 60
Fan Motor RLA A 0.65
Fan Motor
Capacitor
uF 3
Fan Type-Piece Axial-flow 1
Fan Diameter In. 20.47
Defrosting Method Auto Defrost
Climate Type T1
Isolation I
Moisture Protection IP24
Max. Operating Pressure at High Side PSI 550
Max. Operating Pressure at Low Side PSI 175
Sound Pressure Level dB (H/L) A 56
Sound Power Level dB (H/L) A 63
Outdoor Unit Dimensions (WxHxD) In. 38 × 27.6 × 13.4
Package Dimensions (WxHxD) In. 40.5 × 29.53 × 18.03
Net /Gross Weight LBs 114.6/124.5
R410A Refrigerant/
Factory Pre-Charge for 25’
LBs 3.53
Maximum drive IDU NO. 2
WMMS-30CH-V2B(59)4
Total length (actual length) of fitting pipe ≤ 150 ft
Length of farthest fitting pipe ≤ 60 ft
Height difference between
outdoor unit and indoor unit
Outdoor unit
at upper
≤ 60 ft
Outdoor Unit
at lower
≤ 50 ft
Height difference between indoor units ≤ 25 ft

 

Model WMMS-09EL-V2B(59)2
Cooling Capacity Btu/h 9500
Heating Capacity Btu/h 11000
Power Supply V/Ph/Hz 208 / 230 / 1 / 60
Power Consumption W 15
Airflow Volume m3/h 400
CFM 235
Related Current
Heating / Cooling
Amp 0.4
MCA Amp 0.5
MOP Amp 15
Sound
Pressure Level
dB(A) 38
Refrigerant R410A
Connection Pipes
Liquid Connecting Pipe
Diameter
in. Ø1/4
Gas Connecting
Pipe Diameter
in. Ø3/8
Drain Pipe
External Diameter
in. Ø
0.67
Drain Pipe
Internal Diameter
in. Ø
0.59
Dimensions & Weight Indoor Unit
Dimensions (W x D x H) in. 27
5/9 x 8 1/2 x 23 5/8
Net/Gross Weight lbs. 35.3
/ 41.9