YMGI VRF UltraHeating 36000 BTU Mini Split Unit
A VRF SYSTEM THAT STANDS ALONE
YMGI’s UltraHeating VRF systems are designed to deliver comfort year round. Effective in a wide range of outdoor ambient temperatures (as low as -22° F), the YMGI UltraHeating VRF systems can meet all your heating and cooling needs, with no need for a supplemental heating system. A YMGI VRF system can replace traditionally designed gas furnace and AC/HP coil & outdoor unit systems. YMGI UltraHeating VRF systems save money on installation and operation.
Please contact RHNewton’s for a quote on this product
[caldera_form id=”CF5ebd5f0f4edcc”]
Description
Model | Unit | VRFO-36HP-U2B(55)5 |
Cooling Capacity | Btu/h | 36,000 |
Heating Capacity | Btu/h | 45,000 |
Air flow volume | CFM | 3531 |
Heating Capacities at Different OD Ambient Temperatures | 47 ° F | 100% / 45,000 |
17 ° F | 100% / 45,000 | |
-4 ° F | 100% / 45,000 | |
-22 ° F | 80% / 36,000 | |
Sound Pressure Level | dB | 56 |
Power Supply | V/Ø/Hz | 208~230/1/60 |
MCA | A | 37 |
MOP | A | 50 |
Liquid pipe | mm | 9.52 |
inch | 3/8 | |
Gas Pipe | mm | 15.9 |
inch | 5/8 | |
Connection Method | – | Flare Connection |
Refrigerant | – | R410A |
Compressor Manufacturer | – | GREE |
Compressor Type | – | Two-stage Variable Frequency Rotary |
Compressor Quantity | No. | 1 |
Motor Type | – | INVERTER |
Fan Quantity | – | 2 |
SEER (Ducted/Ductless IDUs) | – | 20/16 |
Capacity Adjustment Range | %~% | 15~100 |
Maximum drive IDU NO. | unit | 5 |
Max. Equivalent Connection Pipe Length | feet | 393.7 |
Condenser Fin Color | – | Golden |
Cooling Operation Ambient Temperature Range | ° F | 23 ~ 118 |
Heating Operation Ambient Temperature Range | ° F | -22 ~ 80.6 |
Refrigerant Charge | oz | 229.3 |
Unit Dimensions (WxHxD) | mm | 900 x 1345 x 340 |
inch | 35 3/8 x 53 x 13 3/8 | |
Net Weight | kg | 134.4 |
lbs | 296.4 | |
Low Ambient Cooling Function | – | YES |
Base Pan Heater | – | YES |