DC Inverter 18 SEER, 24,000 Btu/h, 208-230/1/60
Line Sets/Wires Not Included

Out of stock

Description

Series (58)-16 to 22 SEER-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Line Sets/Wires Not Included

Indoor Unit Model: WMMS-24E-V2B(58)2
Outdoor Unit Model: WMMS-24EC-V2B(59)2

DC Inverter 18 SEER, 24,000 Btu/h, 208-230/1/60

System Model WMMS-24K-V2B(58)2
Functions COOLING HEATING
Power Source 208~230/1/60
Nominal heating capacity (ID 70/60 OD 47/43F) 26000
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD17/15F) 17800
Standard Set-up Tested in Lab-Heating capacity (ID 70/60 OD 5F) 15400
Frequency(Hz) (High/Standard/Low) 100/60/15
Power Input (W) (High/ Standard/Low) 2650/1700/400 2750/1790/500
Rated Current (A) (High/ Standard) 12.7/8.2 13.2/8.6
SEER / HSPF (Btu/h.w) 18.0 10.2
EER (Btu/h.w) 12
Dehumidifying Volume (Pints/Hr.) 5.5
Indoor Unit (IDU) Model of Indoor Unit WMMS-24EC-V2B(59)2
Power Supply Voltage/Ph/Hz 208-230/1/60
Allowed Voltage Range 187-253V
Cooling Capacity (Btu/h) High/Standard/Low 26500/22800/9600
Heating Capacity (Btu/h) ID 70/60, OD 47/43F 27400
ID 70/60, OD 17/15F 23800
ID 70/60, OD 17/5F 20600
SEER Btu/h.W 16
HSPF Btu/h.W 8.2
Duhumidifying Capacity Pints/Hr. 5.28
Air Flow (CFM) High/Medium/Low 694/522/366
Air-throw (Ft.) Horizontal Installation 25-18 Upon Mounting Height/Speed/Temp.
External Static Pressure Water In. 0
Sound Level Pressure dB(A) (H/M/L) 45/43/41
Power dB(A) (H/M/L) 55/53/51
Fan Motor Model FN35B-1
Shaft Single
Speed (RMP, H/M/L) 570/520/280
Output (W) 50
Input (W) 165
Capacitor (uF) 3
Fan Wheel Type-Piece Centrifugal-1
Diameter x Height (In.) 17.7 x 4.4
Swing/Step Motor Model MP35CB
Piece 2
Output (W) 2
Input Power of Ele. Heater Type-W NA
Electrical Protection Fuse PCB / Transformer T3.15A 250V / 0.2A
Evaporator Coil Type Alu. Fin/Inner Grooved Copper Tube
Color Blue
Copper Line Connections Sealed by Dry Nitrogen Yes
Flare/Nut-Liuqid + Gas 3/8″ + 5/8″
Drain Hose Connection OD (In.) 1.22
Condensate Pump Installed-Lift (In.) Yes-25
Refrigerant Environmentally Friendly R410A Yes
Filter Type-Feature Standard-Washable
Size WxH (In.) – Qty. 21.38 x 21.34 – 1
Clean Coil Surface Anti-Mildew Function Yes
Pre-heating Function Anti-Cold Blowing Yes
Memory of Previous Set-ups Power is Lost/Resumed Yes
Auto-Restart Function If Power is Resumed Yes
Unit Dimensions Net L x W x H (In.) 33.1 x 33.1 x 9.4
Package L x W x H (In.) 37.8 x 37.8 x 12.2
Unit Weight Net (LBs) 66
Packaged (LBs) 84
Face Panel Dimensions Net L x W x H (In.) 37.4 x 37.4 x 2.4
Package L x W x H (In.) 40.9 x 40.4 x 4.5
Face Panel Weight Net (LBs) 14
Packaged (LBs) 22
Outdoor Unit(ODU) Model of Outdoor Unit WMMS-24C-V2B(58)2
Compressor Manufacturer Sanyo, Mitisubishi or Equivalent
Compressor Model C-6RZ146H1A
Compressor Type Twin Rotary DC
L.R.A. (A) 41
Compressor RLA(A) 8.4
Compressor Power Input(W) 1640
Overload Protector 1NT11L-3979
Throttling Method Electronic Expansion Valve
Fuse Circuit Breaker of HVAC Type 30
Starting Method Transducer starting
Recommended Working Ambient Temp Range (°F) 15°F ≤ T ≤115 °F 5°F ≤ T ≤86 °F
Condenser Coil Type Aluminum fin-copper tube
Coil-Copper Pipe Diameter (In) 0.28
Rows-FPI 2-18.2
Coil Length (L) x Height (H) x Depth (D) (In) 38.1×29.4×1.5
Fan Motor Speed (rpm) (H/L) 780/500
Output of Fan Motor (W) 90
Fan Motor RLA (A) 0.90
Fan Motor Capacitor (uF) 4
Air Flow Volume of Outdoor Unit CFM 2480
Fan Type-Piece Axial-1
Fan Diameter (In) 21.7
Defrosting Type Auto defrost
Designed for Climate Type T1
Isolation I
Moisture Protection IP24
MAX. Operating Pressure for the Discharge Side (PSIG) 551
MAX. Operating Pressure for the Suction Side (PSIG) 174
Sound Pressure Level dB (A) (H/M/L) 56
Sound Power Level dB (A) (H/M/L) 66
Connection Pipe (In) Outer Diameter Liquid Pipe (In) 1/4
Outer Diameter Gas Pipe (In) 5/8
Max Distance ID Above/Blow OD (Ft.) 50/60
Max Distance Length (Ft.) 100
If Not Marked on Nameplate, Refrigerant Pre-charged for Copper Line Length 25
Check Pressure at Trial Running Add or Deduct Refrigerant 0.38
Dim. & Weight- Indoor Unit Dimensions-Net W x H x D (Inches) 39.7 X 12.4 X 8.6
Dimensions of Carton Box W x H x D (Inches) 42.2 X 15.6 X 12.3
Gross / Net Weight (LBs) 46.3/35.3
Dim. & Weight- Outdoor Unit Dimensions-Net W x H x D (Inches) 36.2 X 31.1 X 14.6
Dimensions of Carton Box W x H x D (Inches) 41.9 X 33.1 X 19.0
Gross / Net Weight (LBs) 132/119
Container Loading Assumed-One Model/Container Sets (20’/40’/40’HQ) 47/96/114
Certification Safety Approval (Third Party) ETL (C & US)
Performance Approval (Third Party) AHRI

Important Notes:

  1. Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
  2. Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
  3. Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.