YMGI WMMS-30K-V2B(57)3 M1
$1,550.00
Series (57)-16 SEER-M1-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Cooling Ambient Temperature Down to 25 °F
Line Sets/Wires Not Included
Indoor Unit Model: WMMS-30E-V2B(57)3 M1
Outdoor Unit Model: WMMS-30C-V2B(57)3 M1
DC Inverter 16 SEER, 30,000 Btu/h, 208-230/1/60
Out of stock
Description
Series (57)-16 SEER-M1-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Cooling Ambient Temperature Down to 25 °F
Line Sets/Wires Not Included
Indoor Unit Model: WMMS-30E-V2B(57)3 M1
Outdoor Unit Model: WMMS-30C-V2B(57)3 M1
DC Inverter 16 SEER, 30,000 Btu/h, 208-230/1/60
ACCESSORIES
- THERMOSTAT
- MOUNTING BRACKETS
- FOOT RISERS
- COPPER/WIRE/ACC.SET
- LINESET COVERS
- WINTER WIND BAFFLE
Indoor Unit | WMMS-30E-V2B(57)3 | |||
Outdoor Unit | WMMS-30C-V2B(57)3 | |||
Power supply | V/Ph/Hz | 208-230V/1/60Hz | ||
Cooling | Nominal Capacity | Btu/h | 28000 | |
Input | W | 2980 | ||
Rated current | Amp. | 13.0 | ||
EER | Btu/h.w | 9.4 | ||
SEER | Btu/h.w | 15.0 | ||
Heating | Capacity | Btu/h | 28000 | |
Input | W | 2730 | ||
Rated current | Amp. | 11.9 | ||
COP | W/W | 3.00 | ||
HSPF | Btu/h-w | 8.50 | ||
Minimum Circuit Ampacity | Amp. | 20 | ||
MAX HVAC Type Circuit Breaker |
Amp. | 30 | ||
Compressor | Model | ATL232UDPC9AUL | ||
Type | Rotary | |||
Brand | HIGHLY | |||
Capacity | Btu/h | 22246 | ||
Input | W | 2070 | ||
Rated current(RLA) | Amp. | 8.8 | ||
Refrigerant oil/oil charge | ml | HAF68D1C or equivalent 630±20ml |
||
Indoor fan motor | Model | YDK-50C-4P 1 | ||
Brand | CG | |||
Input | W | 86 | ||
RLA | Amp. | 0.42 | ||
LRA | Amp. | 0.71 | ||
Winding Resistance | Ω | 87.4/76.6 | ||
Capacitor | uF | 2.5 | ||
Speed (Hi/Me/Lo) |
rpm | 1350±20 1150±20 910±20 |
||
Indoor air flow (Hi/Me/Lo) | CFM | 735 / 626 / 490 | ||
Indoor noise level (Hi/Me/Lo) |
dB(A) | 50 | ||
Indoor unit | Dimension (WxDxH) | Inch | 45x12x9 | |
Packing WxDxH) | Inch | 49x16x13 | ||
Net/Gross weight |
lbs. | 39/45 | ||
Outdoor fan motor | Model | YDK-150-6CH 1 | ||
Brand | CG | |||
Input | W | 238 | ||
RLA | Amp. | 1.04 | ||
LRA | Amp. | 1.33 | ||
Winding Resistance | Ω | 49/49.3 | ||
Capacitor | uF | 5 | ||
Speed | Rpm/M | 800/600 | ||
Outdoor air flow | CFM | 2235 / 1676 | ||
Outdoor noise level | dB(A) | 59 / 44 | ||
Outdoor unit | Dimensions (WxDxH) | Inch | 38.18” x 14.76” x 31.06” | |
Packing (WxDxH) | Inch | 44x19x35 | ||
Net/Gross weight | lbs. | 132/143 | ||
R410A Refrigerant charge | Oz | 70.56 | ||
Refrigerant precharge maximum pipe length | Ft. | 25 | ||
Additional charge for each ft. | Oz | 0.23 | ||
Design pressure | PSIG | 510/250 | ||
Refrigerant piping | Liquid side/ Gas side |
Inch | 3/8”+5/8″ | |
Max. refrigerant pipe length | Ft. | 49.2 | ||
Max. difference in level | Ft. | 16.4 | ||
Connection wires between IDU and ODU | 4×AWG18 | |||
Control Type | Remote Control | |||
Operation Temperature Ranges | Indoor (cooling/ heating) | °F | 61~90 | |
Outdoor (cooling / heating) |
°F | AC: 15~115 / HP: -4 ~ 75 |
||
Application area (cooling standard) |
Sq. ft. | 398~700 |
Important Notes:
- Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
- Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
- Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.