YMGI WMMS-36K-V2B(57)3 M1

$2,200.00

Series (57)-16 SEER-M1-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Cooling Ambient Temperature Down to 25 °F
Line Sets/Wires Not Included

Indoor Unit Model: WMMS-36E-V2B(57)3 M1
Outdoor Unit Model: WMMS-36C-V2B(57)3 M1

DC Inverter 16 SEER, 36,000 Btu/h, 208-230/1/60

Out of stock

Description

Series (57)-16 SEER-M1-DC Inverter Heat Pump Mini Split Set (Indoor Unit, Outdoor Unit, Remote Control)
Cooling Ambient Temperature Down to 25 °F
Line Sets/Wires Not Included

Indoor Unit Model: WMMS-36E-V2B(57)3 M1
Outdoor Unit Model: WMMS-36C-V2B(57)3 M1

DC Inverter 16 SEER, 36,000 Btu/h, 208-230/1/60

ACCESSORIES

  • THERMOSTAT
  • MOUNTING BRACKETS
  • FOOT RISERS
  • COPPER/WIRE/ACC.SET
  • LINESET COVERS
  • WINTER WIND BAFFLE
Indoor Unit WMMS-36E-V2B(57)3
Outdoor Unit WMMS-36C-V2B(57)3
Power supply V/Ph/Hz 208-230V/1/60Hz
Cooling Nominal Capacity Btu/h 32000
Input W 3600
Rated current Amp. 15.6
EER Btu/h.w 9.1
SEER Btu/h.w 15.0
Heating Capacity Btu/h 33000
Input W 3110
Rated current Amp. 13.5
COP W/W 3.10
HSPF Btu/h-w 9.50
Minimum Circuit Ampacity Amp. 21
MAX HVAC Type
Circuit Breaker
Amp. 30
Compressor Model ATL253UDPC9AU
Type Rotary
Brand HIGHLY
Capacity Btu/h 24430
Input W 2240
Rated current(RLA) Amp. 9.4
Refrigerant oil/oil charge ml HAF68D1C or equivalent
830±20ml
Indoor fan motor Model YDK-50C-4P 6
Brand CG
Input W 99
RLA Amp. 0.49
LRA Amp. 0.77
Winding Resistance Ω 86.9/87.3
Capacitor uF 2.5
Speed
(Hi/Me/Lo)
rpm 1250±20
1050±20
900±20
Indoor air flow (Hi/Me/Lo) CFM 824 / 692 / 593
Indoor
noise level (Hi/Me/Lo)
dB(A) 53
Indoor unit Dimension (WxDxH) Inch 57x14x11
Packing WxDxH) Inch 63x17x14
Net/Gross
weight
lbs. 53/60
Outdoor fan motor Model MDR-9538-910A
Brand XN
Input W 100
RLA Amp. /
LRA Amp. /
Winding Resistance Ω /
Capacitor uF /
Speed Rpm/M 790
Outdoor air flow CFM 2235 / 1676
Outdoor noise level dB(A) 59 / 44
Outdoor unit Dimensions (WxDxH) Inch 38.18” x 14.76” x 31.06”
Packing (WxDxH) Inch 44x19x35
Net/Gross weight lbs. 152/163
R410A Refrigerant charge Oz 116.48
Refrigerant precharge maximum pipe length Ft. 25
Additional charge for each ft. Oz 0.23
Design pressure PSIG 510/250
Refrigerant piping Liquid side/
Gas side
Inch 3/8”+5/8″
Max. refrigerant pipe length Ft. 49.2
Max. difference in level Ft. 16.4
Connection wires between
IDU and ODU
4×AWG18
Control Type Remote Control
Operation Temperature Ranges Indoor (cooling/ heating) °F 61~90
Outdoor
(cooling / heating)
°F AC: 15~115 /
HP: -4 ~ 75
Application area
(cooling standard)
Sq. ft. 463~850

Important Notes:

  1. Performance rated for matched system at standard conditions-cooling ID 80/67°F, OD 95°F; heating ID 70/60°F, OD 47/43°F. Unit performance varies when weather changes from the standard one.
  2. Select equipment capacity sizes per space load calculation schedule and cooling & heating hours. Not to over size or under size equipment.
  3. Watch unit operation during extreme weather conditions in summer and winter. wind baffle helps system cooling & heating performance in low ambient temperatine ranges.