YMGI WMMS-18K-V2B(78)1

$1,550.00

Does not include Line Sets/ Wires

YMGI DC INVERTER SOLO
Single Zone-Wall Mounted Indoor Unit
The (78)1 Series is designed to work for any single room application.The Wall Mounted evaporator unit provides quiet and efficient heating and cooling and features an LED display that shows the set temperature and operating mode. A motorized louver system distributes air evenly throughout your living or work environment.

YMGI DC INVERTER SOLO
Single Zone-Outdoor Unit
The SOLO (78)1 Outdoor Units have SEER ratings of 17.6 to 23.3 with heating and cooling capacities of 9k to 36k. The Outdoor Units are powered by 208-230 volt, 1 phase, 60Hz. The (78)1 Series is ideal for large open spaces that only require a single heating and cooling zone, such as studio apartments, garages, gyms, offices, etc. (78)1 Outdoor Units are precharged with environmentally friendly R410A refrigerant. The compact design allows for ground installation, or mounting on a wall, under a deck or even on a balcony.

Simple To Install
The (78) Series Heat Pump units the indoor unit uses an integrated mounting plate and requires a 3” hole for conduit. Conduit houses the refrigerant pipes, electrical wiring, and condensate drain hose.

Description

System Model No. WMMS-18K-V2B(78)1
ODU Model No. WMMS-18C-V2B(78)1
IDU Model No. WMMS-18E-V2B(78)1
Climate/Tech T1/INVERTER

Performance

Voltage, Frequency, Phase V/Hz/Ph 208~230/60/1
Cooling Capacity Rating Btu/h 18000
Cooling Capacity Ranges Btu/h 6500-19500
Heating Capacity Rating Btu/h 19000
Heating Capacity Ranges Btu/h 6500-20000
Rated Input-Cooling W 1385
Rated Input-Heating W 1595
SEER Btu/h/ W 23.3
HSPF Heating 11.6
EER for Cooling W/W 13.00
COP for Heating Btu/h /W 11.90
Moisture Removal pts/hr. 3.2
Air Circulation CFM 647.43
R410A Refrigerant charge volume Oz 54.7
Indoor Sound Pressure (H/M/L/silence) dB (A) 48/45/40/36
Outdoor Sound pressure dB (A) 55
Airflow Indoor Unit (S/H/M/L) CFM 635/577/482/383
Airflow Outdoor Unit (H) CFM 1648.01
Cooling Rated Current Amp. 6.3
Heating Rated Current Amp. 7.2
Cooling Current Ranges Amp. 1.5 – 12
Heating Current Ranges Amp. 1.5 – 12
Minimum Current Ampacity (MCA) Amp. 15
MAX. Operating Pressure for
the Discharge Side at Cooling
PSIG 551
MAX. Operating Pressure for
the Suction Side at Cooling
PSIG 174
Maximum Fuse Size(MFS) Amp. 20

Electrical System

Compressor type Rotary
Compressor MFG GMCC
Expansion Device capillary
Compressor model # ATM150D43UFZ
Indoor DC motor Yes
Indoor motor MFG Weiling
Indoor motor model # K1B310497
Indoor motor power output W 35
Indoor motor speed S/H/M/L RPM 1200/1040/880
Outdoor DC motor Yes
Outdoor motor MFG Broad-ocean
Outdoor motor model # DG13Z2D-04
Outdoor motor power input W 60
Outdoor motor speed H/M/L RPM 840/650/500

Evaporator

Evaporator material Copper tube & Aluminum Fin
Number of rows 2
Tube outside dia.and type in. Ø 9/32, innergroove tube
Evaporator LxHxW in. 33 5/32 x 14 7/8 x 1 1/8
Tube pitch(a)x row pitch(b) in. 27/32 x 17/32
Fin spacing in. 1/16

Condenser

Condenser material Copper tube & Aluminum Fin
Number of rows 2
Tube outside dia.and type in. Ø 9/32
Tube type innergroove tube
Condensor LxHxW in. 35 1/4 x 24 13/16 x 3/4 + 34 9/64 x 24 13/16 x 3/4
Tube pitch (a) x row pitch (b) in. 53/64 x 23/32
Fin spacing in. 1/16
Liquid Pipe Diameter in. 1/4
Gas Pipe Diameter in. 1/2
ODU Cooling Working Temperature Range °F 5° – 115°
ODU Heating Working Temperature Range °F -4° – 75°
IDU Remote Cooling Temperature Range °F 61° – 86°
IDU Remote Heating Temperature Range °F 61° – 86°
Performance Testing Standard ARI 210-240
Certifications ETL/AHRI

Packaging

Indoor Unit
Dimensions WxHxD
in. 43.31 x 12.81 x 9.63
Outdoor Unit Dimensions WxHxD in. 33.88 x 25.56 x 12.19
Indoor Unit Weight Net/Gross lbs 32/37.5
Outdoor Unit Weight Net/Gross lbs 99.2/108
Indoor Unit Packing
Dimensions WxHxD (With pipe)
in. 46.06 x 15.38 x 12.44
Outdoor Unit Packing
Dimensions WxHxD (With pipe)
in. 39.19 x 28.75 x 17.5